Wow v3.71 that's like what 10 years old. This from the Knowledge Base. Error 13 GLWDAA 0510 File=gl2xxx.soa Entry Type: Informational Product:Sage MAS 90 ERP, Sage MAS 200 ERP Application: General Ledger Version Reported: 3.71 Subject: Error 13 GLWDAA 0510 File=gl2xxx.soa Possible Resolution: Rename and manually reinitialize the files GL2xxx.soa and GL3xxx.soa (where xxx=company code). How to manually reinitialize data files: Note: This method is generally safer than the "How to reinitialize data files" procedure after it. A file cannot be manually reinitialized unless it is first renamed or moved. Accidentally reinitializing the wrong file is much less likely using this procedure. In Windows Explorer, open ...\Mas90\MAS_xxx\yyxxx folder (where xxx = company code and yy = module code). Rename the files to be reinitialized (for example, rename AR_InvoiceHeader.m4t to AR_InvoiceHeader.bad) . Move the renamed files from the ...\MAS90\ directory. In MAS 90, expand Library Master, Utilities, and click Reinitialize Data Files. Note: In earlier versions, expand Library Master, Repair, and double-click Reinitialize Data Files. Review the warning message, and click OK. Click the Manual button. Type the file name (for example, AR_InvoiceHeader.m4t), and press ENTER. Click Proceed. Note: If the file still exists, the message "File Already Defined" occurs. Either the wrong file was renamed in Windows Explorer (or the correct file in the wrong location), or the wrong file was specified in Reinitialize Data Files.
↧